Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: https://open.mgimo.ru/handle/123456789/19607
Название: SkyScan 1172 X-ray micro-CT scanner of well-core digital modeling for geophysical analysis of landscape polystructures
Моделирование цифрового керна с помощью рентгеновского микро-КТ сканера SkyScan 1172 для геофизического анализа ландшафтных полиструктур
Авторы: Kadyrov, M.
Zavatsky, M.D.
Neelova, E.
Ponomarev, A.
Bikalenko, M.
Кадыров, М.
Завацкий, М.Д.
Неелова, Е.
Пономарев, А.
Бикаленко, М.
Ключевые слова: X-ray micro-CT
well-core digital modeling
geophysical analysis
landscape polystructures
Digital Petrophysics
scanning resolution
reconstruction settings
SkyScan 1172
рентгеновская микро-КТ
цифровое моделирование керна
геофизический анализ
ландшафтные полиструктуры
цифровая петрофизика
разрешение сканирования
настройки реконструкции
SkyScan 1172
Дата публикации: 2022
Библиографическое описание: Kadyrov M., Zavatsky M. D., Neelova E., Ponomarev A., Bikalenko M. SkyScan 1172 X-ray micro-CT scanner of well-core digital modeling for geophysical analysis of landscape polystructures. Geology Ecology and Landscapes. 2022. https://doi.org/10.1080/24749508.2022.2131959
Кадыров М., Завацкий М. Д., Неелова Е., Пономарев А., Бикаленко М. Моделирование цифрового керна с помощью рентгеновского микро-КТ сканера SkyScan 1172 для геофизического анализа ландшафтных полиструктур. Geology Ecology and Landscapes. 2022. https://doi.org/10.1080/24749508.2022.2131959
Аннотация: The present study deals with algorithms for the acquisition of a well-core digital model that is used in the Digital Well-Core technology or “Digital Petrophysics.” The study involved the initial implementation stage of this technology: identification of geometric dimensions of a sample and spatial scanning resolution, as well as of scanning and reconstruction settings to examine a well core in a SkyScan 1172 X-ray micro-CT system. Well-core samples 30 mm wide (7 µm/pixel resolution), 10 mm wide (4 µm/pixel resolution) and 5 mm wide (1.5 µm/pixel resolution) were examined by X-ray micro-computed tomography. The porosity coefficient of all samples was measured by the water-saturation and weighing method. The digital models were used to estimate the porosity coefficient compared to the standard method. The results demonstrated that the best convergence of micro-CT and standard method data was achieved with 5-mm samples at a 1.5 µm/pixel scan resolution. A study on digital model optimization through noise reduction in the NRecon standard software was also conducted and discovered that the best convergence of porosity coefficients was attained when smoothing was set at 8. The scanning and reconstruction settings proposed for well-core samples can be used to implement the Digital Well-Core technology.
Настоящее исследование посвящено алгоритмам получения цифровой модели керна, используемой в технологии «Цифровой керн» или «Цифровая петрофизика». Исследование включало начальный этап внедрения этой технологии: определение геометрических размеров образца и пространственного разрешения сканирования, а также настроек сканирования и реконструкции для изучения керна в рентгеновской микро-КТ системе SkyScan 1172. Образцы керна шириной 30 мм (разрешение 7 мкм/пиксель), шириной 10 мм...
URI: https://open.mgimo.ru/handle/123456789/19607
ISSN: 2474-9508
Располагается в коллекциях:Статьи сотрудников МГИМО во внешних журналах

Файлы этого ресурса:
Нет файлов, ассоциированных с этим ресурсом.
Источник: Geology Ecology and Landscapes  (2022)


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.